Significance and Use | ||||||||||||||||||||
5.1 This is not a routine test. The values recorded are applicable only to the pipe being tested and at the time of testing. |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This practice covers procedures for testing installed non-perforated, gasketed corrugated high-density polyethylene (HDPE) pipelines using either water infiltration or exfiltration acceptance limits to demonstrate the integrity via the level of leakage of the installed materials, construction procedures and installation qualityvia the level of leakage. Pipe to be tested under this practice shall include corrugated HDPE drainage pipe meeting the requirements of AASHTO M 252, AASHTO M 294 and Specification F2306/F2306M. 1.2 The values stated in SI units
are to be regarded as the standard. The values in parentheses are
mathematical conversions to inch-pounds, which are provided for
informational purposes only and are not considered standard.
1.3 This test method shall be performed on lines after all connections and service laterals have been plugged and braced adequately to withstand the test pressures. The time between completion of the backfill operations and testing shall be specified by the approving authority. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. The testing required under this standard necessitates operating in confined spaces. The user must insure that all OSHA and local safety codes are duly observed. |
||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-09-13 (Number of items: 2 429 660)
© Copyright 2024 NORMSERVIS s.r.o.