We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Test Method for Determining the Uniformity of the Luminance of an Electroluminescent Lamp or Other Diffuse Lighting Device
STANDARD published on 1.7.2012
Designation standards: ASTM F2964-12
Note: WITHDRAWN
Publication date standards: 1.7.2012
SKU: NS-54792
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Colours and measurement of lightOther standards related to lamps
Keywords:
color, colorimeter, diffuse light, electroluminescent material, luminance, membrane switch, photometer, planar light source, radiometer, uniformity, video photometer, ICS Number Code 17.180.20 (Colours and measurement of light), 29.140.99 (Other standards relating to lamps)
Significance and Use | ||||
4.1 Application of an EL lamp (or other diffuse lighting source) to illuminate a device has a functional purpose and must meet specifications to satisfy the functional requirements of the device. 4.2 Illumination of the device or application can be affected by variations in the quality, efficiency, and design of the lamp and any attendant mounting or shading fixtures. 4.3 This test method addresses only the optical and visual appearance of the lamp and not its electrical function. 4.4 This test method is non-destructive. 4.5 This test method is described for application to the illumination layer in which case the results apply to that layer only. However, it may be desirable and practical to apply the test to a further assembly or to a fully assembled device with built in illumination. In such a case, the results refer specifically to the subassembly or the entire device respectively. |
||||
1. Scope | ||||
1.1 This test method covers procedures for determining the uniformity of the luminance of an electroluminescent (EL) lamp. While written specifically for the purpose of evaluating EL devices, which are intrinsically very uniform, it can be applied (judiciously) to the measurement of any diffuse, essentially planar, light source. For specific purposes, it can be applied to partially assembled devices into which the illumination is installed (such as a membrane switch) as a diagnostic for the performance of the entire device. In such a case it must be understood that the results pertain only to the partial assembly and will be modified as the further assembly proceeds. 1.2 The method is to take a 2-dimensional set of measurements, sampling the surface of the unit under test with appropriate density. The method is restricted to measuring luminance only, since variations in color will also show as luminance non-uniformity especially in any photoptically calibrated measuring device. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||
2. Referenced Documents | ||||
|
Historical
1.3.2008
Historical
1.6.2013
Historical
1.11.2013
Historical
15.6.2012
Historical
1.4.2009
Historical
15.6.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.