Standard Specification for Metric Outside Diameter Polyethylene (PE) Plastic Pipe (DR-PN) (Includes all amendments And changes 11/21/2016).
Automatically translated name:
Standard Specification for Metric Outside Diameter Polyethylene (PE) Plastic Pipe (DR-PN)
STANDARD published on 1.11.2015
Designation standards: ASTM F3123-15a
Note: WITHDRAWN
Publication date standards: 1.11.2015
SKU: NS-623643
The number of pages: 11
Approximate weight : 33 g (0.07 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
DR, HDB, HDPE, HDPE pipe, HDS, metric pipe, metric sized pipe, MRS, non-pressure pipe, OD controlled, PE100, PE4710, PE pipe, plastic pipe, PN, polyethylene pipe, pressure pipe,, ICS Number Code 23.040.20 (Plastic pipes)
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This specification covers metric outside diameter polyethylene (PE) pipe made from polyethylene compound that qualifies for MRS, HDB and HDS ratings and for PE100 and PE4710 designations. Included are requirements for polyethylene compound, workmanship, dimensions, short-term stress and ductility, long-term stress, marking, quality assurance and verification of joining. 1.1.1 Polyethylene pipe in accordance with this specification is intended to be compatible with nominal diameters and nominal pressures in accordance with ISO 161-1 and wall thickness in accordance with ISO 4065. 1.2 Pipes produced under this specification are intended for the pressure or non-pressure conveyance of liquid or gaseous media. Pipes produced under this specification are not intended as enclosures for electrical or communications components. See Appendix X1. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-03-12 (Number of items: 2 232 189)
© Copyright 2025 NORMSERVIS s.r.o.