Standard Practice for Operating Enclosed Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials
STANDARD published on 1.12.2010
Designation standards: ASTM G153-04(2010)
Note: WITHDRAWN
Publication date standards: 1.12.2010
SKU: NS-57445
The number of pages: 7
Approximate weight : 21 g (0.05 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
accelerated, accelerated weathering, carbon arc, durability, enclosed carbon arc, exposure, laboratory weathering, light, lightfastness, nonmetallic materials, temperature, ultraviolet, weathering, Accelerated weathering, Carbon-arc light exposure, Durability, Enclosed carbon-arc, Laboratory aging/weathering, Light exposure, Lightfastness, Nonmetallic materials, Ultraviolet (UV) analysis--nonmetallic materials, Weathering, ICS Number Code 19.040 (Environmental testing)
Significance and Use | ||||||||||||||||||
The use of this apparatus is intended to induce property changes associated with the end use conditions, including the effects of sunlight, moisture, and heat. These exposures may include a means to introduce moisture to the test specimen. Exposures are not intended to simulate the deterioration caused by localized weather phenomena, such as atmospheric pollution, biological attack, and saltwater exposure. Alternatively, the exposure may simulate the effects of sunlight through window glass. Typically, these exposures would include moisture in the form of humidity. Cautions—Refer to Practice G151 for full cautionary guidance applicable to all laboratory weathering devices. Variation in results may be expected when operating conditions are varied within the accepted limits of this practice. Therefore, no reference shall be made to results from the use of this practice unless accompanied by a report detailing the specific operating conditions in conformance with Section 10. It is recommended that a similar material of known performance, a control, be exposed simultaneously with the test specimen to provide a standard for comparative purposes. It is recommended that at least three replicates of each material evaluated be exposed in each test to allow for statistical evaluation of results. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This practice covers the basic principles and operating procedures for using enclosed carbon-arc light and water apparatus intended to reproduce the weathering effects that occur when materials are exposed to sunlight (either direct or through window glass) and moisture as rain or dew in actual use. This practice is limited to the procedures for obtaining, measuring, and controlling conditions of exposure. A number of exposure procedures are listed in an appendix; however, this practice does not specify the exposure conditions best suited for the material to be tested. Note 1—Practice G151 describes performance criteria for all exposure devices that use laboratory light sources. This practice replaces Practice , which describes very specific designs for devices used for carbon-arc exposures. The apparatus described in Practice is covered by this practice. 1.2 Test specimens are exposed to enclosed carbon arc light under controlled environmental conditions. 1.3 Specimen preparation and evaluation of the results are covered in various methods or specifications for specific materials. General guidance is given in Practice G151 and ISO 4892-1. More specific information about methods for determining the change in properties after exposure and reporting these results is described in ISO 4582. 1.4 The values stated in SI units are to be regarded as the standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.5.1 Should any ozone be generated from the operation of the light source, it shall be carried away from the test specimens and operating personnel by an exhaust system. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-21 (Number of items: 2 216 840)
© Copyright 2024 NORMSERVIS s.r.o.