We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Use of a Polymethylmethacrylate Dosimetry System
STANDARD published on 1.6.2010
Designation standards: ASTM/ISO 51276-12
Note: WITHDRAWN
Publication date standards: 1.6.2010
SKU: NS-870
The number of pages: 7
Approximate weight : 21 g (0.05 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
absorbed dose, dose, dosimeter, dosimetry system, electron beam, gamma radiation, ionizing radiation, irradiation, PMMA, polymethylmethacrylate, radiation, radiation processing, radiation sterilization, ICS Number Code 17.240 (Radiation measurements)
Significance and Use |
The PMMA dosimetry system provides a means for measuring absorbed dose based on a change in optical absorbance. PMMA dosimetry systems are commonly used in industrial radiation processing, for example in the sterilization of medical devices and the irradiation of foods. |
1. Scope |
1.1 This is a practice for using polymethylmethacrylate (PMMA) dosimetry systems to measure absorbed dose in materials irradiated by photons or electrons in terms of absorbed dose to water. The PMMA dosimetry system is classified as a routine dosimetry system. 1.2 The PMMA dosimeter is classified as a Type II dosimeter on the basis of the complex effect of influence quantities (see ASTM Practice E2628). 1.3 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ASTM E2628 “Practice for Dosimetry in Radiation Processing” for a PMMA dosimetry system. It is intended to be read in conjunction with ASTM E2628. 1.4 This practice covers the use of PMMA dosimetry systems under the following conditions: 1.4.1 the absorbed dose range is 0.1 kGy to 150 kGy. 1.4.2 the absorbed dose rate is 1 × 10−2 to 1 × 107 Gy·s−1. 1.4.3 the photon energy range is 0.1 to 25 MeV. 1.4.4 the electron energy range is 3 to 25 MeV. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-23 (Number of items: 2 217 157)
© Copyright 2024 NORMSERVIS s.r.o.