Standard CISPR 16-1-3-ed.2.0 28.6.2004 preview

CISPR 16-1-3-ed.2.0

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power



STANDARD published on 28.6.2004


Language
Format
AvailabilityIN STOCK
Price315.30 USD excl. VAT
315.30 USD

The information about the standard:

Designation standards: CISPR 16-1-3-ed.2.0
Publication date standards: 28.6.2004
SKU: NS-116246
The number of pages: 63
Approximate weight : 189 g (0.42 lbs)
Country: International technical standard
Category: Technical standards CISPR

The category - similar standards:

EmissionImmunity

Annotation of standard text CISPR 16-1-3-ed.2.0 :

This part of CISPR 16 is designated a basic standard, which specifies the characteristics and calibration of the absorbing clamp for the measurement of radio disturbance power in the frequency range 30 MHz to 1 GHz. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. In this edition a more detailed calibration method for the absorbing clamp is specified. Furthermore, new alternative calibration methods are introduced which are more practicable than the one which was specified previously. Additional parameters to describe the absorbing clamp are defined, like the decoupling factor for the broadband absorber (DF) and the decoupling factor for the current transformer (DR), along with their validation methods. A procedure for the validation of the absorbing clamp test site (ACTS) is also included in the document. The contents of the corrigendum of February 2006 have been included in this copy. La presente partie de la CISPR 16 est une norme fondamentale qui specifie les caracteristiques et letalonnage de la pince absorbante pour la mesure de la puissance perturbatrice radioelectrique dans la gamme de frequences de 30 MHz a 1 GHz. Cette deuxieme edition annule et remplace la premiere edition parue en 2003. Elle constitue une revision technique. Cette edition specifie une methode detalonnage plus detaillee pour la pince absorbante. De plus, de nouvelles methodes detalonnage possibles sont introduites, qui sont plus praticables que celle qui etait specifiee auparavant. Des parametres additionnels pour decrire la pince absorbante sont definis, tels le facteur de decouplage pour labsorbeur large bande "DF" et le facteur de decouplage pour le transformateur de courant "DR", avec leurs methodes de validation. Une procedure pour la validation du site dessai a la pince absorbante (ACTS) est aussi incluse dans le document. Le contenu du corrigendum de fevrier 2006 a ete pris en consideration dans cet exemplaire.

These changes apply to this standard:

CISPR 16-1-3-ed.2.0/Amd.1 Change

Amendment 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power
(Amendement 1 - Specifications des methodes et des appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Partie 1-3: Appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Materiels auxiliaires - Puissance perturbatrice)

Change published on 31.3.2016

Selected format:

Show all technical information.
26.80 USD


IN STOCK
CISPR 16-1-3-ed.2.0/Amd.2 Change

Amendment 2 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power
(Amendement 2 - Specifications des methodes et des appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Partie 1-3: Appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Materiels auxiliaires - Puissance perturbatrice)

Change published on 28.1.2020

Selected format:

Show all technical information.
13.40 USD


IN STOCK

These corrections apply to this standard:

CISPR 16-1-3-ed.2.0/Cor.1 Correction

Corrigendum 1 - Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power
(Corrigendum 1 - Specifications des methodes et des appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Partie 1-3: Appareils de mesure des perturbations radioelectriques et de l´immunite aux perturbations radioelectriques - Materiels auxiliaires - Puissance perturbatrice)

Correction published on 9.2.2006

Selected format:

Show all technical information.
1.30 USD


IN STOCK

We recommend:

Technical standards updating

Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.

Would you like to know more? Look at this page.




Cookies Cookies

We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.

You can refuse consent here.

Here you can customize your cookie settings according to your preferences.

We need your consent to use the individual data so that you can see information about your interests, among other things.