Gas-fired central heating boilers - Part 2-2: Specific standard for type B1 appliances
Translate name
STANDARD published on 1.1.2025
Designation standards: ČSN EN 15502-2-2
Classification mark: 075316
Catalog number: 520210
Publication date standards: 1.1.2025
SKU: NS-1209370
The number of pages: 60
Approximate weight : 180 g (0.40 lbs)
Country: Czech technical standard
Category: Technical standards ČSN
This document specifies, the requirements and test methods concerning the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners and are hereafter referred to as "boilers".
Where the word boiler is used, this is intended to be read as the boiler including its connecting ducts, ducts and terminals, if any.
This document covers gas-fired central heating boilers type B11, B11BS, B12, B12BS, B13, B13BS:
NOTE 1 - For further background information on appliance types see EN 1749:2020.
a) that have a nominal heat input (on the basis of net calorific value) not exceeding 70 kW;
b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437:2021;
c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation;
d) where the maximum operating pressure in the water circuit does not exceed 6 bar;
e) which are declared in the technical instructions to be either a "low temperature boiler" or a "standard boiler". If no declaration is given the boiler is to be considered a "standard boiler";
f) which are intended to be installed inside a building or in a partially protected place;
g) which are intended to produce also hot water either by the instantaneous or storage principle, as a single unit;
h) which are designed for either sealed water systems or for open water systems.
NOTE 2 - This document provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this document, the risk associated with this alternative construction needs to be assessed.
An example of an assessment methodology, based upon risk assessment, is given in Clause 11.
This document does not cover all the requirements for:
NOTE - Negative pressure relative to the pressure in the flue system can for example be caused by mechanical or thermal ventilation in airtight buildings