Safety in installations for electroheating and electromagnetic processing - Part 6: Particular requirements for high frequency dielectric and microwave heating and processing equipment
Translate name
STANDARD published on 1.9.2024
Designation standards: ČSN EN IEC 60519-6-ed.3
Classification mark: 335002
Catalog number: 519579
Publication date standards: 1.9.2024
SKU: NS-1195702
The number of pages: 76
Approximate weight : 228 g (0.50 lbs)
Country: Czech technical standard
Category: Technical standards ČSN
This part of IEC 60519 is applicable to equipment using high frequency or microwave energy alone or in combination with other kinds of energy for industrial heating and processing of materials. It is also applicable to HF and MW generators made available to users as separate units.
This part is applicable to equipment operating in the frequency range 3 MHz to 300 GHz, with the following limitations.
- This document applies to only high frequency dielectric heating and processing as defined in 3.1.103. It does not apply to induction heating, which it is possible to carry out in the lower part of the specified frequency band and is covered by IEC 60519-3, with magnetic field safety aspects addressed in IEC TS 62997:2017, the latter to be replaced by a technical report (TR) or by a revised technical specification (TS).
- The ISM centre frequencies for dielectric heating and processing of industrial interest are narrow bands about 6,78 MHz, 13,56 MHz, 27,12 MHz and 40,68 MHz. Different field emission measurement procedures and limiting values are applicable, depending on the processing frequency in the high frequency range 3 to 300 MHz. Specifications are in Annex BB.
- This document specifies limits for microwave emission only for the ISM frequencies between 800 MHz and 6 MHz, as specified in Annex CC. For other microwave frequencies the basic restriction and IEC 62311 apply.
- The foundations for compliance with emission values are the basic restrictions, referred to in the IEEE/ANSI C95.1:2019 and Directive 2013/35/EU. However, maximum HF processing frequency electric and magnetic field values are taken from the IEEE/ANSI C95.1:2019 standard, as indicated in Annex BB.
- This document is not applicable to: