We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Low-voltage electrical installations - Part 7-714: Requirements for special installations or locations - External lighting installations
STANDARD published on 14.12.2011
Designation standards: IEC 60364-7-714-ed.2.0
Publication date standards: 14.12.2011
SKU: NS-410001
The number of pages: 20
Approximate weight : 60 g (0.13 lbs)
Country: International technical standard
Category: Technical standards IEC
IEC 60364-7-714:2011 applies to the selection and erection of luminaires and lighting installations forming part of an outdoor fixed installation. The origin of the external lighting installation is the supply delivery point of electrical energy by the supply authority or the origin of the circuit supplying the external lighting installation exclusively. The requirements apply to, for example, lighting installations for roads, parks, gardens, places open to the public, sporting areas, illumination of monuments, floodlighting, telephone kiosks, bus shelters, advertising panels, town plans and road signs. The requirements do not apply to: - public street-lighting installations which are part of the public power grid; - temporary festoon lighting; - road traffic signal systems; - and luminaires which are fixed to the outside of a building and are supplied directly from the internal wiring of that building. This second edition cancels and replaces the first edition, published in 1996, and constitutes a technical revision. The major technical changes with respect to the previous edition are listed below: - clause numbering is aligned with present structure of IEC 60364; - additional protection is required in some cases of equipment incorporating lighting; - more stringent requirements regarding IP degree of protection; - introduction of particular requirements for isolation. La CEI 60364-7-714:2011 sapplique au choix et a la mise en oeuvre des luminaires et des installations declairage faisant partie dune installation exterieure fixe. Lorigine des installations declairage exterieur est le point de livraison de lenergie electrique par le distributeur ou lorigine du circuit qui alimente exclusivement linstallation declairage exterieur. Les exigences sappliquent, par exemple, aux installations declairage des rues, parcs, jardins, lieux publics, terrains de sport, pour lillumination des monuments, pour leclairage par projection, aux installations declairage des cabines telephoniques, abris dautobus, panneaux publicitaires, plans de ville et panneaux de signalisation routiere. Les exigences ne sappliquent pas: - aux installations declairage public qui font partie du reseau de distribution public; - aux guirlandes lumineuses temporaires; aux systemes de signalisation routiere; - et aux luminaires fixes a lexterieur des batiments et alimentes directement de linterieur de ces batiments. Cette seconde edition annule et remplace la premiere edition, publiee en 1996 dont elle constitue une revision technique. Les modifications principales par rapport a ledition precedente sont les suivantes: - la numerotation des articles est alignee sur celle de la CEI 60364; - une protection additionnelle est exigee dans certains cas dappareillages comportant des luminaires; - les exigences concernant les degres de protection IP sont renforcees; - et des exigences particulieres pour le sectionnement ont ete introduites.
16.5.2013
16.5.2013
23.4.2013
18.9.2008
18.9.2008
18.9.2008
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-04-28 (Number of items: 2 197 482)
© Copyright 2025 NORMSERVIS s.r.o.