We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Coordination of electrical protections of substantions and traction units
Translate name
STANDARD published on 1.2.2022
Designation standards: IRS 70797-1ed.
Publication date standards: 1.2.2022
SKU: NS-1054442
The number of pages: 46
Approximate weight : 138 g (0.30 lbs)
Country: International technical standard
Category: Technical standards IRS
The present IRS covers substations and traction units of modern interoperable design for traction units. In particular, it applies to the electrical protection system, provided for the following AC and DC (see Abbreviations and Symbols - page 6) electric traction systems, according to IEC 60850 (see Reference documents - page 5): - 25 kV - 50 Hz; - 25 kV - 60 Hz; - 15 kV - 16 2/3 Hz; - 1.500 V DC; - 3.000 V DC. The present IRS: - establishes railway specific protection principles; - describes the railway specific protection system functionality; - describes the protection system in relation to the electric traction system, which also comprises the interface information between the electric traction system and the electric rolling stock; - specifies principles for operation coordination of circuit breakers in substations and on-board tractive units. Coordination is required because: - the cut-out power of train-borne circuit breakers is limited whereas the level of short circuit currents may exceed it under some power supply voltages; - if there is no OCL voltage, the tractive unit circuit breakers must open within a maximum predefined time; - the conditions for automatic re-closing of substation circuit breakers must be compatible with the preceding conditions. Interoperability of traction units on electrified railways using different systems requires that the compatibility of the protection systems between traction unit and substation is verified, regardless of the rail network in question. Moreover, this document specifies the limit condition of the input filter load current on tractive units under direct current power supply so that substation circuit breakers will not trip unnecessarily. A software model has been created during the drafting of this IRS. It can be easily adapted to other use cases. It is available with the IRS download file.
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2025-01-08 (Number of items: 2 218 384)
© Copyright 2025 NORMSERVIS s.r.o.