Methods for automatic ultrasonic testing for welds of ferritic steel
Translate name
STANDARD published on 30.6.1998
Language | |
Format |
|
Availability | IN STOCK |
Price | ON REQUEST excl. VAT |
ON REQUEST |
Designation standards: JIS Z3070:1998
Publication date standards: 30.6.1998
SKU: NS-1083238
The number of pages: 22
Approximate weight : 66 g (0.15 lbs)
Country: Japanese technical standard
Category: Technical standards JIS
This Standard specifies the system, the methods for testing and images of test results in the case of automatically performing the ultrasonic angle beam using the 1-probe or 2-probe pulse reflection technique for complete welds of ferritic steel with a thickness of over 6 mm. However, the Standard shall not apply to welds tube joints being in manufacturing process and welds of nuclear power plants.History:1998-05-20 Established 2004-03-20 Confirmed 2008-10-01 Confirmed 2013-10-21 Confirmed 2018-10-22 Confirmed 2023-10-20 Confirmed