We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Dissolved Molecular Oxygen in Liquid Hydrocarbons by Electrochemical Detection
STANDARD published on 11.1.2005
Designation standards: UOP 678-04
Publication date standards: 11.1.2005
SKU: NS-574852
The number of pages: 8
Approximate weight : 24 g (0.05 lbs)
Country: American technical standard
Category: Technical standards UOP
1. Scope |
This method is for estimating the dissolved oxygen in liquid hydrocarbons by electrochemical detection. The preferred application is online analysis, although the analysis may also be performed in the laboratory. The lower detection limit is 0.1 mass-ppm while the upper limit is dependent on the solubility of oxygen in the specific sample. Carbon dioxide, ammonia, hydrogen sulfide, and mercaptans at concentrations above 200, 300, 15 and 15-ppm (see Note 1) respectively, will interfere with the oxygen determination. Materials that contaminate the membrane or volatile components that are either oxidized, reduced, or react with the sensor electrodes will also interfere. The sampling system associated with a process unit is to be specified depending on the specific process unit. |
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)