We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Trace Desorbent in C10-C18 Molex Products by GC
STANDARD published on 29.7.2002
Designation standards: UOP 863-01
Publication date standards: 29.7.2002
SKU: NS-574954
The number of pages: 6
Approximate weight : 18 g (0.04 lbs)
Country: American technical standard
Category: Technical standards UOP
1. Scope |
Molex is an adsorptive separation process that separates normal paraffins from branched chain and cyclic hydrocarbons. This method is for determining trace amounts of Molex desorbent (n-pentane, isooctane, p-xylene) in C10-C18 Molex products. The lower limit of detection for n-pentane and isooctane is 5 mass-ppm. Early eluting Molex product may cause interference at the p-xylene site. Therefore, the lower limit of detection for p-xylene can be as high as 50 mass-ppm. |
Do you want to be sure about the validity of used regulations?
We offer you a solution so that you could use valid and updated legislative regulations.
Would you like to get more information? Look at this page.
Latest update: 2024-07-26 (Number of items: 2 339 085)
© Copyright 2024 NORMSERVIS s.r.o.