We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Nickel, Tungsten, Sodium and Aluminum in Hydrocracking Catalysts by ICP-AES
STANDARD published on 29.7.2002
Designation standards: UOP 924-00
Publication date standards: 29.7.2002
SKU: NS-574991
The number of pages: 8
Approximate weight : 24 g (0.05 lbs)
Country: American technical standard
Category: Technical standards UOP
1. Scope |
This method is for determining nickel(Ni), tungsten(W), sodium(Na) and aluminum(Al) in fresh alumina or alumino-silicate supported catalysts by inductively coupled plasma atomic emission spectroscopy (ICP-AES). The method is suitable for the determination of elements from the low ppm to high mass percent concentration ranges. The determination of Ni, W, Na and Al is described herein, however, many other elements which are brought into solution during the described sample decomposition can be also determined. Because of incomplete dissolution, catalysts containing alpha- or theta-alumina phases cannot be analyzed by this method, however, it can be applied if a modified sample dissolution technique, such as a TeflonTM lined pressure vessel (not described herein) is utilized. This method can also be used for spent catalyst after suitable pretreatment. |
Latest update: 2025-03-14 (Number of items: 2 232 255)
© Copyright 2025 NORMSERVIS s.r.o.