We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Guide for Evaluation of the Effectiveness of Hand Hygiene Topical Antimicrobial Products using ex vivo Porcine Skin
STANDARD published on 15.11.2012
Designation standards: ASTM E2897-12
Note: WITHDRAWN
Publication date standards: 15.11.2012
SKU: NS-46221
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Other standards related to microbiologyChemicals for industrial and domestic disinfection purposes
Keywords:
antibacterial, contaminants, cup scrub, efficacy, handwashes, healthcare, pigskins, resident microorganisms, transient microorganisms, ICS Number Code 07.100.99 (Other standards related to microbiology), 71.100.35 (Chemicals for industrial and domestic desinfection purposes)
Significance and Use | ||||||
5.1 The guide may be used to demonstrate the effectiveness of topical antimicrobial products using pigskin as a surrogate for human skin and the cup scrub technique for sampling. 5.2 The techniques described can be used to simulate Test Method E1174 and will use the pigskin substrate to overcome limitations posed by exposure of human subjects to potentially pathogenic microorganisms, while offering the benefit of applicability to a wide variety of hand-washing conditions that cannot be simulated in test tubes. 5.3 Use of the pigskin surrogate offers less expensive and higher throughput screening. |
||||||
1. Scope | ||||||
1.1 This guide is designed to demonstrate the effectiveness of hand hygiene topical antimicrobial products using pigskin as a surrogate model. 1.2 Knowledge of microbiological techniques is required for these procedures. 1.3 This standard guide can be used to evaluate topical antimicrobial handwash or handrub formulations. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Historical
1.4.2008
Historical
1.12.2012
Historical
1.7.2013
Historical
1.12.2011
Historical
15.2.2011
Historical
1.8.2011
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.