We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Specification for Folded/Formed Poly (Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation
STANDARD published on 10.9.2002
Designation standards: ASTM F1871-11
Note: WITHDRAWN
Publication date standards: 10.9.2002
SKU: NS-51904
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
installation, underground, plastic pipe, thermoplastic, poly (vinyl chloride) (PVC) plastic pipe, rehabilitation, trenchless technology,Poly(vinyl chloride)(PVC) pipe--specifications, Folded PVC pipe, Rehabilitation--sewerlines, Sewer pipe (thermoplastic)--specifications, Underground installation--water supply/distribution systems, Conduits--specifications, ICS Number Code 23.040.20 (Plastic pipes), 83.080.20 (Thermoplastic materials)
1. Scope | ||||||||||||||||||||||||||||||
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded/formed poly (vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation. 1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is installed into and then expanded to provide a close fit to the wall of the original conduit, forming a new structural pipe-within-a-pipe. Note 1—For installation procedures refer to Practice F 1867. 1.3 This specification includes pipe made only from materials specified in Section 6. This specification does not include pipe manufactured from reprocessed, recycled, or reclaimed PVC. 1.4 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are provided for information only. 1.5 The following precautionary statement pertains only to the test method portion, Section 11, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.6 There is no similar or equivalent ISO Standard. |
||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||
|
Historical
1.8.2013
Historical
1.3.2010
Historical
1.12.2010
Historical
1.5.2011
Historical
1.4.2012
Historical
1.3.2011
Latest update: 2024-11-22 (Number of items: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.