We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Comparing Particle Size in the Use of Alternative Types of Particle Counters
STANDARD published on 1.1.2013
Designation standards: ASTM F660-83(2013)
Note: WITHDRAWN
Publication date standards: 1.1.2013
SKU: NS-56042
The number of pages: 5
Approximate weight : 15 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
particle counters, Strokes diameter, ICS Number Code 19.120 (Particle size analysis. Sieving)
Significance and Use | ||||||
4.1 This practice supports test methods designed to evaluate the performance of fluid-filter media, for example, Practice F796 wherein particle size distributions are addressed and at the same time this practice provides a means to compare size measurements obtained from several different types of instruments. 4.2 The factor for converting one kind of diameter scale to another is only valid for the specific test particles studied. |
||||||
1. Scope | ||||||
1.1 This practice provides a procedure for comparing the sizes of nonspherical particles in a test sample determined with different types of automatic particle counters, which operate on different measuring principles. 1.2 A scale factor is obtained by which, in the examination of a given powder, the size scale of one instrument may be multiplied to agree with the size scale of another. 1.3 The practice considers rigid particles, free of fibers, of the kind used in studies of filtration, such as: commercially available test standards of quartz or alumina, or fly ash, or some powdered chemical reagent, such as iron oxide or calcium sulfate. 1.4 Three kinds of automatic particle counters are considered: 1.4.1 Image analyzers, which view stationary particles under the microscope and, in this practice, measure the longest end-to-end distance of an individual particle. 1.4.2 Optical counters, which measure the area of a shadow cast by a particle as it passes by a window; and 1.4.3 Electrical resistance counters, which measure the volume of a particle as it passes through an orifice in an electrically conductive liquid. 1.5 This practice also considers the use of instruments that provide sedimentation analyses, which is to say provide measures of the particle mass distribution as a function of Stokes diameter. The practice provides a way to convert mass distribution into number distribution so that the meaning of Stokes diameter can be related to the diameter measured by the instruments in 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Historical
1.9.2010
Historical
1.5.2010
Historical
15.11.2006
Historical
1.11.2012
Historical
1.8.2012
Historical
1.4.2010
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-11-26 (Number of items: 2 206 223)
© Copyright 2024 NORMSERVIS s.r.o.