We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.
Standard Practice for Identifying Elements by the Peaks in Auger Electron Spectroscopy (Withdrawn 2017)
Automatically translated name:
Standard Practice for Identifying Elements by the Peaks in Auger Electron Spectroscopy
STANDARD published on 1.10.2008
Designation standards: ASTM E827-08
Note: WITHDRAWN
Publication date standards: 1.10.2008
SKU: NS-48142
The number of pages: 4
Approximate weight : 12 g (0.03 lbs)
Country: American technical standard
Category: Technical standards ASTM
Keywords:
AES, Auger electron spectroscopy, spectroscopy, surface analysis, Surface analysis--spectrochemical analysis, Auger electron spectroscopy (AES), ICS Number Code 71.040.50 (Physicochemical methods of analysis)
Significance and Use | ||||||||||
Auger analysis is used to determine the elemental composition of the first several atomic layers, typically 1 to 5 nm thick, of a specimen surface. In conjunction with inert gas ion sputtering, it is used to determine the sputter depth profile to a depth of a few micrometres. The specimen is normally a solid conductor, semiconductor, or insulator. For insulators, provisions may be required for control of charge accumulation at the surface (see Guide E 1523). Typical applications include the analysis of surface contaminants, thin film deposits or segregated overlayers on metallic or alloy substrates. The specimen topography may vary from a smooth, polished specimen to a rough fracture surface. Auger analysis of specimens with volatile species that evaporate in the ultra-high vacuum environment of the Auger chamber and substances which are susceptible to electron or X-ray beam damage, such as organic compounds, may require special techniques not covered herein. (See Guide E 983.) |
||||||||||
1. Scope | ||||||||||
1.1 This practice outlines the necessary steps for the identification of elements in a given Auger spectrum obtained using conventional electron spectrometers. Spectra displayed as either the electron energy distribution (direct spectrum) or the first derivative of the electron energy distribution are considered. 1.2 This practice applies to Auger spectra generated by electron or X-ray bombardment of the specimen surface and can be extended to spectra generated by other methods such as ion bombardment. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historical
1.6.2010
Historical
1.5.2014
Historical
1.11.2006
Historical
1.11.2011
Historical
1.11.2013
Historical
1.4.2012
Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.
Would you like to know more? Look at this page.
Latest update: 2024-12-22 (Number of items: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.